Product details

In demanding industrial environments such as wind farms and rail transit, power stability is directly tied to the operational safety of core equipment. The Santak C3KS-M PLUS 2 industrial UPS, leveraging second-generation Castle technology with a 3kVA/2400W output, is specifically engineered to tackle power supply challenges in harsh conditions. Its ultra-wide input voltage range (115-300VAC) adapts to severe grid fluctuations in wind farms, maintaining continuous power supply for over 625ms even when voltage dips to 20% of nominal levels, fully complying with the mandatory low-voltage ride-through (LVRT) requirements outlined in the 'Technical Regulations for Wind Farm Integration into Power Systems.'To address the unique challenges of the wind power industry—high dust, salt spray corrosion, and temperature variations from -25°C to 60°C—this model employs PCBA triple-protection coating for moisture and mold resistance. Critical power components feature redundant designs with a 30% safety margin, ensuring stable output even at 4,000 meters altitude (no derating below 2,000 meters) and under 55°C high-temperature derating conditions. The built-in 6A smart charging module enables rapid battery recovery, while the 96VDC battery system allows flexible backup time extension. Paired with standard RS232 and dry contact communication cards, it achieves remote status monitoring and self-management in unattended scenarios.In scenarios such as rail transit and outdoor smart terminals, its seismic-resistant structure and 0ms utility/battery switching capability provide millisecond-level protection for precision control systems, while the compact 8.3kg design (190×393×328mm) significantly saves equipment space. The Santak industrial-grade solution, certified by TLC, CE, and CQC, is building a power safety barrier for the new energy industry with daily voltage fluctuation accuracy of 0.01% and a comprehensive three-year warranty.

Product Features

  • 1. Supports ultra-wide operating temperature (-25℃~60℃) and storage temperature (-40℃~60℃)
  • 2. Conformal coating process provides triple protection against moisture/salt spray/mold
  • 3. Capable of operating at 4000m altitude (no derating required below 2000m)
  • 4. Redundant design of key components and enlarged margins extend equipment lifespan
  • 5. Ultra-wide input voltage range (115-300VAC) adapts to grid fluctuations
  • 6. 3-year warranty for the whole unit including battery, reducing maintenance costs
  • 7. Certified by TLC/CE/CQC, compliant with industrial safety standards

Application Scenarios

  • 1. Power protection for wind turbine converter control systems
  • 2. Uninterrupted power supply for photovoltaic station inverters and monitoring systems
  • 3. Power support for outdoor smart parcel lockers/terminal cabinets
  • 4. Power protection for rail transit signal systems and control equipment
  • 5. Power backup for new energy storage systems in high-altitude regions
  • 6. Power supply for outdoor surveying equipment and unattended sites
  • 7. Power protection for industrial equipment in coastal salt fog environments

Product Parameters

  • Model:C3KS-M PLUS 2
  • Rated Capacity:3kVA/2400W
  • Input/output configuration:Input/Output System
  • Input configuration:Single Phase
  • Rated voltage:230Vac
  • Voltage range:115-300VAC
  • Frequency:Frequency
  • Power factor:0.99
  • Bypass Voltage:80VAC×(1±5%)~285VAC×(1±5%)
  • Bypass voltage:Default 180VAC×(1±5%)~264VAC×(1±5%)
  • Battery Voltage:96VDC
  • Internal Battery Capacity:Internal battery not included
  • Full Load Backup Time (25℃):Depends on battery capacity
  • Battery Charging Current:6A
  • Communication Interface:Standard RS232, optional communication card (refer to optional accessories list)
  • Output Type:Single Phase
  • Rated Voltage:230VAC
  • Power Factor:0.8
  • Voltage Accuracy:0.01
  • Rated Frequency:50/60 Hz
  • Overload Capacity @ Utility Mode:105%±5%
  • Overload Capacity @ Utility Mode:150%±5%
  • Overload capacity @ Utility mode:>200%±5%, transfer to bypass and alarm in 200ms
  • Transfer time:0ms (Utility?Battery)
  • Transfer Time:<4ms (Utility?Bypass)
  • Operating Temperature:-25°C Utility mode with full load startup -25°C~-10°C Utility mode full load operation -10°C~40°C Battery and Utility mode full load 40°C~60°C Load derating as follows: 40°C~55°C output power derates 3% per 1°C increase. 55~60°C 1K(S): 440W 2K(S): 880W 3K(S): 1320W
  • Humidity:≤2000m no derating, 2000m< altitude ≤4000m load reduces 1% per 100m increase, for applications above 4000m, consult the manufacturer
  • Altitude:Seismic resistance, high/low temperature, salt spray, vibration, altitude, EMC
  • Certification:TLC, CE, CQC energy-saving
  • Dimensions (W×D×H, mm):190*393*328
  • Net Weight (kg):8.3
  • Packaging Dimensions (WxDxH mm):325*493*458
  • Gross Weight (kg):9.8