In wind turbine applications, the Santak Castle Industrial UPS M PLUS series demonstrates strong adaptability. Its ultra-wide input voltage range of 285-498VAC effortlessly handles severe grid fluctuations, while an output accuracy of ±1% ensures precise power supply for sensitive equipment. The device comes standard with an isolation transformer and optional dry contact cards, supporting intelligent monitoring for unmanned scenarios. Its flexible three-in-three-out/three-in-single-out configuration adapts to various industrial loads.The 6-pulse + 5th harmonic filter solution reduces input harmonics to below 10%, with an output crest factor ratio of 0.125. Its overload capability supports 125% load for 10 minutes, providing round-the-clock power protection for photovoltaic station inverter systems, outdoor smart terminal cabinets, and rail transit equipment. The product holds multiple certifications including TLC/CE/CQC, with a 3-year warranty covering battery components. Redundant fans and dust-proof design ensure stable operation in high-dust environments like steel and petrochemical industries. Its unique inductive load capacity and 45-66Hz wide-frequency input effectively address the core challenge of poor grid quality in the renewable energy sector.Whether in extreme cold storage environments of -40℃ or high-temperature operating conditions of 60℃, Santak industrial UPS consistently delivers over 99% conversion efficiency, building a reliable power lifeline for wind turbine pitch systems, outdoor energy storage equipment, and smart unmanned delivery terminals.

Product Parameters

  • Model:SIU 20KVA Industrial UPS
  • Rated Capacity:20KVA
  • KVA/KW:20/18
  • Applicable power system type:TN-S, TN-C, TN-C-S, TT, IT
  • Input/output voltage phase:Three-phase input/three-phase output or single-phase output
  • Input voltage range:Mains input: 380/400/415VAC
  • Input voltage range:Voltage range: 285VAC-498VAC
  • Input frequency range:Rated 50/60Hz, frequency range: 45-66Hz
  • Input current harmonic:6-pulse: ≤30%
  • Input current harmonic:6-pulse plus 5th filter: ≤10%
  • Input current harmonic:12-pulse: ≤10%
  • Input power factor:6-pulse: ≥0.8
  • Input power factor:6-pulse plus 5th filter: ≥0.92
  • Input power factor:12-pulse: ≥0.82
  • Battery to mains transfer time:0 ms
  • Battery topology:Battery directly connected to DC bus
  • Rated battery voltage:DC220V 3/1: (204V,216V,228V)
  • Rated battery voltage:DC384V 3/1: (360V,372V,384V,396V,408V)
  • Rated battery voltage:DC384V 3/3: (360V,372V,384V) (360V,372V,384V,396V,408V)
  • Shared battery at startup:Support
  • Output voltage and accuracy:Single-phase: 220V±1% (230V,240V optional)
  • Output voltage and accuracy:Three-phase: 380V±1% (400V,415V optional)
  • Output frequency and accuracy:Default 50Hz±0.05%. 60Hz optional
  • Output voltage harmonic (refer to EN62040-3 standard):<1% @100% linear load
  • Output voltage harmonic (refer to EN62040-3 standard):<3% @ 100% non-linear load
  • Crest factor ratio:0.125694444
  • Overload:<110% rated load, continuous operation
  • Overload:110%~125% rated load, 10 minutes
  • Overload:125%~150% rated load, 1 minute