Product details

As an expert in industrial power protection, the Santak SIU 200KVA UPS integrates reliability into every detail. Its three-phase input/output design supports precise voltage control of 380V±1%, with output harmonics strictly adhering to the EN62040-3 standard and a crest factor ratio as low as 0.125, ensuring stable operation of sensitive equipment. In wind power scenarios, the device adapts to grid fluctuations with a wide frequency input range of 45-66Hz, coupled with dry contact cards for unattended management, while 12-pulse technology suppresses input harmonics below 10%. The specially designed inductive load overload capability can withstand 125% load for 10 minutes, and the composite coating on critical circuit boards effectively resists high-dust corrosive environments.For scenarios such as outdoor energy storage and rail transit, the product supports flexible configuration of 384VDC battery packs, with optional input transformers for dual isolation protection. The output power covers 180KW industrial loads, meeting the access requirements of various power systems like TN-S/TT, truly achieving zero power interruption protection in harsh environments.

Product Features

  • Adapts to extreme temperatures of -25℃~60℃ and high-altitude environments up to 4000 meters
  • Triple-proof coating technology effectively resists moisture/salt spray/mold
  • Redundant design extends the lifespan of critical components
  • Standard output isolation transformer ensures electrical safety
  • Supports dual DC input modes of 384VDC/220VDC
  • 3-year warranty for the whole unit including battery components
  • Optional dry contact card enables remote unattended management

Application Scenarios

  • Low-voltage ride-through power supply for wind turbine converters and main control systems
  • Power guarantee for photovoltaic inverters and energy storage equipment
  • Uninterrupted operation support for outdoor smart terminal cabinets/parcel lockers
  • Backup power for rail transit signal systems and communication equipment
  • High-dust corrosive scenarios like petrochemical/steel manufacturing
  • Power supply for outdoor surveying instruments and unmanned delivery devices
  • Emergency power maintenance for critical nodes in smart grids

Product Parameters

  • Model:SIU 200KVA Industrial UPS
  • Rated Capacity:200KVA
  • KVA/KW:200/180
  • Applicable power system type:TN-S, TN-C, TN-C-S, TT, IT
  • Input/output voltage phase:Three-phase input/three-phase output or single-phase output
  • Input voltage range:Mains input: 380/400/415VAC
  • Input voltage range:Voltage range: 285VAC-498VAC
  • Input frequency range:Rated 50/60Hz, frequency range: 45-66Hz
  • Input current harmonic:6-pulse: ≤30%
  • Input current harmonic:6-pulse plus 5th filter: ≤10%
  • Input current harmonic:12-pulse: ≤10%
  • Input power factor:6-pulse: ≥0.8
  • Input power factor:6-pulse plus 5th filter: ≥0.92
  • Input power factor:12-pulse: ≥0.82
  • Battery to mains transfer time:0 ms
  • Battery topology:Battery directly connected to DC bus
  • Rated battery voltage:N/A
  • Rated battery voltage:DC384V 3/1: (360V,372V,384V,396V,408V)
  • Rated battery voltage:DC384V 3/3: (360V,372V,384V) (360V,372V,384V,396V,408V)
  • Shared battery at startup:Support
  • Output voltage and accuracy:Single-phase: 220V±1% (230V,240V optional)
  • Output voltage and accuracy:Three-phase: 380V±1% (400V,415V optional)
  • Output frequency and accuracy:Default 50Hz±0.05%. 60Hz optional
  • Output voltage harmonic (refer to EN62040-3 standard):<1% @100% linear load
  • Output voltage harmonic (refer to EN62040-3 standard):<3% @ 100% non-linear load
  • Crest factor ratio:0.125694444
  • Overload:<110% rated load, continuous operation
  • Overload:110%~125% rated load, 10 minutes
  • Overload:125%~150% rated load, 1 minute
Loading...